Microscan EZ Match Imager Manuel d'utilisateur Page 195

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 431
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 194
EZ Match User Manual
8-11
I/O Parameters
1D / Stacked Symbology Qualification
Minimum Number of Bars
Minimum Number of Qualified Scan Lines
Start/Stop Status
Definition: Sets the minimum number of bars to qualify linear symbols.
Serial Cmd: <K717,minimum number of bars,minimum number of qualified scan
lines,start/stop status>
Default: 0
Options: 0 to 255 (0 = disabled)
Definition: Sets the minimum number of scans that have the required number of
bars set in Minimum Number of Bars.
Note: This is a percentage value, from 0 to 100.
Serial Cmd: <K717,minimum number of bars,minimum number of qualified scan
lines,start/stop status>
Default: Disabled
Options: Any number from 0 to 100 (0 = Disabled)
Definition: When enabled, both Start and Stop characters need to be present to
qualify as a decodable symbol. In the case of PDF417, only a Stop needs
to be present.
Note: This parameter does not apply to UPC, GS1 DataBar,
MicroPDF417, or Pharmacode.
Serial Cmd: <K717,minimum number of bars,minimum number of qualified scan
lines,start/stop status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Vue de la page 194
1 2 ... 190 191 192 193 194 195 196 197 198 199 200 ... 430 431

Commentaires sur ces manuels

Pas de commentaire