12-2
EZ Match User Manual
IP Database Serial Commands
IP Database Serial Commands
Number of Active Indexes <K252,number of active database settings>
IP Database Status
<K255,index,shutter speed,gain,focal distance,
sub-sampling,row pointer,column pointer,row
depth,column width,threshold mode,fixed threshold
value,processing mode,narrow margins,background
color,symbology type,color filter,color>
Save Current Settings to Database <K255+,index>
Load Current Settings from Database
<K255-,index>
Request Selected Index Settings <K255?,index>
Request All Database Settings <K255?>
Database Mode
<
K256,
switch mode,frame count/time,image process
looping,image dimensions>