Serial Verification
8-12 MS-3 Laser Scanner User’s Manual
8–Data Outputs
Control/Hex Output
Operational Command Output
Serial Cmd: <K701,serial command echo status,serial command beep sta-
tus,control/hex output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Determines the response to a Serial Command Echo or status request
command.
When set to Control, two characters are transmitted to represent a
non-displayable character. For example, a carriage return will be shown
as the two characters: ^M.
When set to Hex, the output is the hex character.
Usage: Useful for viewing settings with binary characters when using serial
command on a terminal.
Serial Cmd: <K701,serial command echo status,serial command beep status,con-
trol/hex output>
Default: Control
Options: 0 = Control 1 = Hex
Definition: Directs the scanner to bracket non-bar code scanner data such as
counters with command start and stop characters, and echo the com-
mand to the host.
Usage: Useful when brackets are required to delineate certain scanner outputs
such as counters.
Serial Cmd: <K701,status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled