Chapter 8 Data Outputs
MS-3 Laser Scanner User’s Manual 8-15
8–Data Outputs
Beeper Output
Beeper Output Condition
Definition: A beep is emitted either after each good read of a symbol or after each
noread.
Note: Beeper will also sound if any of the following occur:
the scanner is defaulted a send/save command from ESP or an Exit
command from any embedded menu.
•a <Z>, <Zp>, <Zd>, or <K,1> command is sent
Usage: Can be used as an audible verification that either a good read or a
noread has occurred.
Serial Cmd: <K702,beeper output>
Default: On Good
Options: 0 = Disabled
1 = On Good
2 = On Noread