Microscan MS-4X Manuel d'utilisateur Page 191

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 374
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 190
MS-4X Imager User Manual
7-25
I/O Parameters
Trigger Evaluation Period
Number to Output On
Decodes per Trigger Threshold
Definition: The number of triggers to examine for the trend analysis condition.
Serial Cmd:
<
K780,
trend analysis mode,
trigger evaluation period
,number to output on,
decodes per trigger threshold>
Default: 0
Options: 0 to 255
Usage: Example: If Number to Output On is set to 3 and Trend Analysis Mode is
set to No Read, then the output will not be activated until 3 No Reads have
occurred.
Definition: Sets the number of Trend Analysis Mode events (mismatches, No Reads,
or reads/trigger as configured by Trend Analysis Mode) to occur within the
trigger evaluation period before activating the associated output.
Serial Cmd:
<
K780,
trend analysis mode,trigger evaluation period,
number to output on
,
decodes per trigger threshold>
Default: 0
Options: 0 to 255
Definition: When set to this mode, and when the appropriate output is set to output on
trend analysis, the imager will function in a Decodes per Trigger mode
during the read cycle and the trend analysis operation. Output will be activated
based on whether or not the symbol decode count at the end of the read
cycle crosses the decodes per trigger threshold.
Note: Although this setup causes the imager to function in a Decodes per
Trigger mode, the decode count will only be appended to the symbol data if
the status of the Decodes per Trigger command is enabled.
Serial Cmd:
<
K780,
trend analysis mode,trigger evaluation period,number to output on,
decodes per trigger threshold
>
Default: 0
Options: 0 to 65535
Vue de la page 190