Vue de la page 305
13-12
MS-4X Imager Us
er Manual
Master Database
Enter Master Symbol Data
Usage: Allows you to enter master symbol data for any enabled master symbol index
number (1 to 10), provided the total number of characters does not exceed
the maximum allowed.
Serial Cmd: <K231,master symbol number,master symbol data>
Options: Enter data for 1 to 10 symbols (any combination of ASCII text up to the
maximum allowed.
For example, to enter data for master symbol 9, after making certain that
master
symbol database size is enabled for 9 or more symbols, send
<K231,9,data>
.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex
pa
irs. See
ASCII Character Entry Modifier
for a detailed explanation of how
to enter ASCII characters as hex values.
Caution:
If no data is entered, the existing data will be deleted.
ESP: 1. Open the Utilities menu.
2. Set the number of master symbols you want to create in Master Symbo
l
Dat
abase Size.
3. Double-click on each symbol number you want to set up and copy, or type
your data in the popup dialog and click OK.
4. When all your data has been entered, click the Send Database to the
Reader butt
on.