Microscan MS-4X Manuel d'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 374
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
MS-4X Imager User Manual
3-17
Communications
Daisy Chain ID Status
Note: Enable/disable and length must be the same in all readers.
Daisy Chain ID
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K101h,,,,,,,3C>
For >: <K101h,,,,,,,3E>
For
, : <K101h,,,,,,,2C>
See ASCII Character Entry Modifier for a detailed explanation of how to enter ASCII
characters as hex values.
Usage: Used in a daisy chain setup in cases where the host needs to know which
reader in the chain sent the data.
Definition: Each reader in a daisy chain can be assigned a one or two character ID
that will appear in front of decoded data and identify its source.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain i.d.
status, daisy chain i.d.>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Used in a daisy chain setup in cases where the host needs to know which
reader in the chain sent the data.
Definition:
A one or two character prefix which identifies the particular daisy chai
n
r
eader from which the data is being sent to the host.
Serial Cmd:
<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
i.d.
status,daisy chain i.d.>
Default: 1/
Options: Any one or two ASCII characters.
Vue de la page 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 373 374

Commentaires sur ces manuels

Vikitpm 04 Jan 2024 | 14:20:38

urenrjrjkvnm

Evapsi 06 Jan 2024 | 23:41:38

Med