MS-Connect 210 User’s Manual 2-5
Using Ethernet
Configuring Network Parameters (cont.)
4. Look for the default IP address in the Network Destination column. If it does not
appear there, contact your IT department.
5. At the command prompt, type
telnet [MS-Connect 210 IP address] 9999
and type
Enter
.
6. At the Telnet prompt, type Enter.
7. To configure the IP address in the Telnet session, type 0 and Enter.
Note: “Netmask: Number of Bits for Host Port” will appear in the command prompt.
This defines the number of cleared bits (“0” bits) in the LSB (least significant bit) of the
32-bit Netmask, starting at the right.
Example: 255.255.255.0 = 8 “0” bits
255.255.0.0. = 16 “0” bits
255.0.0.0 = 24 “0” bits
8. Follow the command prompts to configure the IP address.
9. When done, type 9 and Enter to save settings.
10. At the command prompt, type ping [MS-Connect 210 IP address] and type Enter.
11. If the MS-Connect 210 responds to the pings, it is ready to communicate.