5-134 QX Hawk Industrial Imager User Manual
I/O Parameters
Decodes per Trigger
When set to this mode, and when the appropriate output is set to output on trend analysis,
the imager will function in a Decodes per Trigger mode during
the read cycle and the
trend analysis operation. Output will be activated
based on whether or not the symbol
decode count at the end of the read cycle is less than the decodes per trigger threshold.
Note: Although this setup causes the imager to function in a Decodes per Trigger mode,
the decode count will only be appended to the symbol data if the status of the Decodes
per Trigger command is enabled.
Example:
Decodes per Trigger threshold: 100
100 or more decodes = No output
Fewer than 100 decodes = Output fires