QX Hawk Industrial Imager User Manual A-53
Appendices
Code 93
Status (Code 93)
Fixed Symbol Length Status (Code 93)
Symbol Length (Code 93)
PDF417
Status (PDF417)
Fixed Symbol Length Status (PDF417)
Fixed Symbol Length (PDF417)
Decode at End of Read Cycle (PDF417)
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: 3 = Both Standard and Edge-to-Edge
Options: 0 = Disabled
1 = Standard
2 = Edge-to-Edge
3 = Both Standard and Edge-to-Edge
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: 10
Options: 1 to 128
Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol
length,unused,decode at end of read cycle>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol
length,unused,decode at end of read cycle>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol
length,unused,decode at end of read cycle>
Default: 10
Options: 1 to 2710
Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol
length,unused,decode at end of read cycle>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled