MS-4 Imager User’s Manual 7-11
I/O Parameters
Symbol Size 1
Symbol Size 2
Symbol Size Tolerance
Definition: Checks for symbol sizes for a specified number of elements. In the case
of rectangular symbols, checks the longer side.
Serial Cmd: <K718,finder pattern status,symbol size mode,symbol size 1,symbol
size 2,symbol size tolerance,dimension mode,dimension 1,dimension
2,dimension tolerance,orientation mode,orientation value>
Default: 10
Options: 8 to 88 elements
Definition: Checks for symbol sizes for a specified number of elements. In the case
of rectangular symbols, checks the shorter side.
Serial Cmd: <K718,finder pattern status,symbol size mode,symbol size 1,symbol
size 2,symbol size tolerance,dimension mode,dimension 1,dimension
2,dimension tolerance,orientation mode,orientation value>
Default: 10
Options: 8 to 88 elements
Definition: Sets the allowable deviation, up or down, for symbol sizes specified in
Symbol Size 1 and Symbol Size 2.
Serial Cmd: <K718,finder pattern status,symbol size mode,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension
2,dimension tolerance,orientation mode,orientation value>
Default: 2
Options: 0 to 10
Vue de la page 166