MS-4 Imager User’s Manual 7-41
I/O Parameters
Power-On / Reset Counts
Note: Power On / Reset Counts is a read only command.
Power-On
Power-On
uses a 16-bit counter that increments each time the Imager is powered-on.
Resets
Resets uses a 16-bit counter that increments each time the Imager is reset. This value is
reset at power-on.
Power-On Saves
Power-On Saves uses a 16-bit counter that increments each time an Imager setting is
saved for power-on with a <Z> command.
Power-On Flash Saves
Power-On Flash Saves uses a 16-bit counter that increments each time an Imager setting
is saved to the customer parameter section of flash memory with a <Zc> command.
Serial Cmd: <K406,power-on,resets,power-on saves,power-on flash saves>
Serial Cmd: <K406,power-on,resets,power-on saves,power-on flash saves>
Serial Cmd: <K406,power-on,resets,power-on saves,power-on flash saves>
Serial Cmd: <K406,power-on,resets,power-on saves,power-on flash saves>