MS-4 Imager User’s Manual 4-3
Calibration
Calibration Options
This command specifies the operation of the Imager’s calibration feature. The default
configuration is set up to perform calibration on gain and symbol type. The default shutter
speed setting is disabled, because not all applications require shutter speed, and when it
is required, the application-specific settings tend to vary widely.
Note: Background Color (page 6-35) is part of the calibration process regardless of the
calibration setup. After successful completion of the calibration routine, the background
color will be set to the appropriate value, depending on the symbol in the field of view. The
Mirrored Image parameter (page 10-28) is not part of the calibration process, and it must
be configured appropriately prior to calibration.
Gain
Definition: When enabled, gain will be calibrated to provide the best available image
quality and performance.
When disabled, gain is fixed and is not part of the calibration process.
Serial Cmd: <K529,gain,shutter speed,symbol type,WOI framing,WOI margin,line
scan height,processing>
Default: Enabled
Options: 0 = Disabled 1 = Enabled