1-4 MS-Connect 210 User’s Manual
Configure the Display
Configure the Display
If you are using a version of the MS-Connect 210 with an alphanumeric character display
(FIS-0210-0001G or FIS-0210-0003G), you must configure the display before applying
power to the system. For the MS-Connect 210’s display to operate correctly, all communication
settings must match those of the reader. Settings can be matched using the dip switches
located on the board at SW3.
Important: The dip switches located at SW4 on the board are FOR FACTORY USE ONLY
and should not be moved.
Display Communication Dip Switches*
* Settings must match reader. Default settings shown in bold italics.
** Sends a Form Feed command (0x0C) to the display, clearing the screen whenever the MS-Connect 210
receives new data. The reader’s Preamble must be set to 0x0C for Clear Screen to function.
Once the MS-Connect 210’s dip switches are configured to match reader settings,
decoded symbol data and other information will display correctly during operation of the
system.
Note: Power must be cycled to the MS-Connect 210 each time the dip switch settings for
baud rate are changed.
BAUD RATE DATA
BITS
PARITY CLEAR
SCREEN
SWITCH 9.6K 19.2K 38.4K 57.6K 115.2K 7 8 EVEN/ODD NONE YES NO
1 OFF ON ON ON ON
2 ON OFF OFF ON ON
3 ON OFF ON OFF ON
4-5 NOT USED
6
ON
**
OFF
7 OFF ON
8 ON OFF
Display
Communication
Dip Switches