2-16 MS-Connect 210 User’s Manual
EtherNet/IP Serial Interface (Class 0x68)
Send Length
This parameter specifies the length of the send data. The maximum number of bytes that
can be sent in one message is 470 bytes.
Receive Length
This parameter specifies the largest amount of receive data the host can accept. It is only
effective in the Send_with_Response service. In a Send_with_Response or
Get_Attribute_Single reply it indicates the number of data bytes actually included in the
message. The Get_Attribute_Single reply will contain all the bytes available in the receive
queue up to the maximum. The maximum number of bytes that can be received in one
message is 470 bytes.
Receive Idle Timeout
This parameter specifies the longest amount of idle time in milliseconds (ms) the host is
willing to wait once any data is available. It is only effective in the Send_with_Response
service. For the Get_Attribute_Single service this value is assumed to be 0. A value of 0 is
used for immediate idle timeout and the service will reply immediately after data is available.
A value of 255 (FF in hex) disables the idle timeout. In a Send_with_Response reply it
indicates the number of milliseconds of idle time the firmware actually waited for additional
receive data.
Send Flags
The Send Flags field gives the host some additional controls over the serial output.
Flushing the output queue allows the host to remove outgoing data and replace it with
newer or higher-priority data.
Receive Flags
The Receive Flags field gives the host some additional controls over the serial input. It is
only effective in the Send_with_Response service.
Flushing the input queue allows the host to remove irrelevant data that was collected by
the communication adapter.
Bit (0 = LSB) Status Flag
0 Flush — Flushes the serial output queue before sending the data
enclosed in the message.
1-7 Reserved
Bit (0 = LSB) Status Flag
0 Flush — Flushes the serial input queue before receiving new
incoming data.
1-2 Reserved
3 Framing — Serial protocol framing is enabled (see Frame Trailer
(Postamble) Flags). This bit can be checked in the response to see
if the correct frame format was received.
4-7 Reserved