Laser High Warning
10-6 MS-3 Laser Scanner User’s Manual
10–Diagnostics
Laser High Warning
When enabled, a message is transmitted whenever the laser current exceeds a fac-
tory-calibrated reference value which cannot be altered. The message repeats once
every 30 minutes until the condition is corrected.
Laser High Status
Laser High Message
Definition: Enables the Laser High message.
Usage: Alerts the user to impending laser failure. (Contact Microscan Service.)
Serial Cmd: <K400,warning message status,laser high status,laser low status,
novram/reset warning status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Defines the Laser High message.
Serial Cmd: <K404,laser high message>
Default: HI-LASR
Options: Any 1 to 10 character ASCII string except NUL, <, or >.