Chapter 3 Protocol
MS-3 Laser Scanner User’s Manual 3-11
3–Protocol
Intercharacter Delay
Definition: The time interval in milliseconds between individual characters trans-
mitted from the scanner to the host.
Usage: Intercharacter Delay is only used where a host cannot receive data
quickly enough and there is enough time between symbols to allow
data to be completely transferred. It is rarely used since any setting
other than zero will slow down communications. For example, a 200
setting will result in a 1/5 second delay between each character that is
transmitted.
Serial Cmd: <K144,intercharacter delay>
Default: 0
Options: 0 to 255 (in milliseconds). Zero (0) causes no delay between characters.