MS-4X Imager User Manual
6-29
Symbologies
Postal Symbologies
Important: Postal Symbologies must have a minimum pixels-per-element value of 4 to
be decoded reliably by the MS-4X.
The imager must be configured to specific read range, field of view, and camera parameters
before decoding Postal Symbologies.
For optimal decode results with a Standard Density (SD) imager:
•Set Focal Distance and set gain and shutter settings for a high contrast image.
Position the imager 3.5” to 6” from the symbol (5-10” if Pixel Sub-Sampling is disabled).
Position the symbol as close to the center of the imagers field of view as possible.
Note: Measurements based on a 16 mil (60 dpi) POSTNET symbol.
Position the
postal symbol in
the center of the
imager’s field of
view.