MS-4X Imager User Manual
4-17
Calibration
Fine-Tune Pass
The theory behind Fine-Tune Pass is to dial in a decoded symbol based on the range
supplied by the Medium Pass.
Running Fine Tune Pass
Prog Rating Decode Quality Focus Shutter Gain Locate
77 6416 3 104 386 250 38 7
79 6424 3 112 386 250 39 6
81 6424 3 112 386 250 40 6
84 6432 3 120 386 250 41 6
86 6448 3 136 386 250 42 5
88 6464 3 152 386 250 43 5
90 6476 3 164 386 250 44 5
93 6488 3 176 386 250 45 5
95 6506 3 194 386 250 46 6
97 6524 3 212 386 250 47 5
100 6538 3 226 386 250 48 6
Rating List (Best):
Rating = 6527; Focus = 386; Shutter = 250; Gain = 48
Rating = 6517; Focus = 386; Shutter = 250; Gain = 47
Rating = 6505; Focus = 386; Shutter = 250; Gain = 46
Rating = 6491; Focus = 386; Shutter = 250; Gain = 45
Rating = 6476; Focus = 386; Shutter = 250; Gain = 44
Rating = 6462; Focus = 386; Shutter = 250; Gain = 43
Rating = 6449; Focus = 386; Shutter = 25
0; Gain = 42
Calibration PASSED.
urenrjrjkvnm
Med