Device Control
Device Control by Serial Command
Output 1 Pulse
Sending <L1> activates the link between Output 1 (+) and Output 1 (–) of the host connector
(regardless of Master Symbol or Output 1 status).
Output 2 Pulse
Sending <L2> activates the link between Output 2 (+) and Output 2 (–) of the host connector
(regardless of Master Symbol or Output 2 status).
Output 3 Pulse
Sending <L3> activates the link between Output 3 (+) and Output 3 (–) of the host connector
(regardless of Master Symbol or Output 3 status).
Disable Reader
Sending <I> will turn the imager OFF, end the current read cycle, and will not allow the
imager to enter another read cycle until turned ON. This feature is useful during extended
periods of time when no symbols are being decoded, or the imager is being configured.
Disabling the imager will not affect any commands that have already been downloaded.
Enable Reader
Sending <H> will turn the imager ON and allow it to enter read cycles.
Click the Utilities button and then the Device Control
tab to display the Device Control view.
The Output 1 Pulse, Output 2
Pulse, and Output 3 Pulse buttons
activate the link between the + and –
of the host connector. The buttons in
the Extras section Disable or Enable
the reader.