MS-4X Imager User Manual
7-17
I/O Parameters
Default on Power-On
Load Configuration Database
Save for Power-On
Definition: When enabled, if the EZ button is held down on power-on the imager will
default to customer defaults and save for power-on. This is the same as
sending a <Zrc> command.
Serial Cmd: <K770,global status,default on power-on,load Configuration Database,
save for power-on>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Allows the user to load the Configuration Database with calibration results.
When the user performs a calibration using the EZ button, all the database
entries are moved down one index and the results of the calibration are
saved to index 1. The results will be saved as current settings as well.
Serial Cmd: <K770,global status,default on power-on,load Configuration Database,
save for power-on>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: If enabled, after calibration is complete, all parameters will be saved for
power-on.
Serial Cmd: <K770,global status,default on power-on,load Configuration Database,
save for power-on>
Default: Disabled
Options: 0 = Disabled 1 = Enabled