Lifetime Hours
9-12 MS-9 Scanner User’s Manual
Lifetime Hours
A message can be defined that will be transmitted whenever the scanners elapsed time
clock exceeds the set hours threshold. The message repeats one time every 30 min
-
utes.
Hours Threshold
Note: Hours entered are 1/10 of the actual hours.
Message
Usage: Used for setting up a preventive maintenance program.
Definition: A user can set a time in hours that will cause a message to be sent when-
ever the scanner’s run time exceeds this value.
The elapsed time is the time the scanner is powered up.
Serial Cmd: <K401,hours10,message>
Default: 2500 (x 10 = 25,000 hours)
Options: 0 to 65534
Definition: The user can enter a message of up to 10-characters that will be dis-
played whenever the hours threshold is reached or exceeded.
Serial Cmd: <K 401,hours10,message>
Default: SERVICE
Options: Any 1 to 10 character ASCII string except NUL, <, or >.