Counts
9-4 MS-9 Scanner User’s Manual
Counts
(These commands are READ ONLY.)
Power-on
Resets
Usage: Used for detecting unwanted resets caused by power supply problems or
ESD transients.
Definition Returns the number of times the scanner has been re-powered or a
watchdog reset occurs.
Serial Cmd: Send <K406?>
Returns <K_power-ons,resets>
Read Only
Ranges:
0 to 65,535 power-ons.
Usage: Used for detecting unwanted resets caused by power supply problems or
ESD transients.
Definition Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware
defaults. A watchdog reset is a reset that is forced whenever the software
locks-up.
Serial Cmd: Send <K406?>
Returns <K_power-ons,resets>
Read Only
Ranges:
0 to 65,535 resets.