Partial Output
8-8 MS-9 Scanner User’s Manual
Partial Output
Partial Output Status
Start Position (Partial Output)
Length (Partial Output)
Usage: In Multisymbol mode, partial output is performed on each separate
symbol. For example, if Start Position is set to 3 and Partial Length is
set to 5, the following symbols are transmitted as follows:
1234567890 as 34567
1234 as 34
123456789,abcde as “34567,cde” (two symbols with separator)
12 as [blank]
Definition: When enabled, allows you to pre-select portions of symbols to be transmit-
ted by the scanner.
Serial Cmd: <K703,status,start postion,length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Allows you to determine the first character from the beginning of a sym-
bol to transmit.
Serial Cmd: <K703,status,start postion,length>
Default: 1
Options: 1 to 63
Definition: Allows you to determine the number of characters to be transmitted.
Serial Cmd: <K703,status,start postion,length>
Default: 63
Options: 1 to 63