Operation Command Output
8-10 MS-9 Scanner User’s Manual
Operation Command Output
Important: This option must be enabled for ESP to operate.
Disabled
When set to disabled, the start and stop brackets < and > are not sent with responses
to the operational commands such as <T> and <N> and utility commands such as
counters and part number requests do not function.
Enabled
Directs the scanner to bracket non-bar code scanner data such as counters with com-
mand start and stop characters, and echo the command to the host.
Usage: Used when brackets are required to delineate certain scanner outputs
such as counters.
Definition: Controls the output of command brackets.
Serial Cmd: <K738,status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled