Microscan MS-96 Manuel d'utilisateur Page 80

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 226
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 79
Symbologies by Serial Command
5-12 MS-9 Scanner User’s Manual
Check Digit Type (Codabar)
Modulus 16
Used in the photo-finishing market.
NW 7
Used in Japanese markets.
Check Digit Output Status (Codabar)
Definition: Allows the user to select the check digit type Codabar will use.
Serial Cmd: <K471,status,start & stop match,start & stop match output,large
intercharacter gap,fixed symbol length status,fixed symbol
length,check digit type,check digit output>
Default: Disabled
Options: 0 = Disabled
1 = Modulus 16
2 = NW 7
3 = Both
Usage: For additional security a check digit can be added to the symbol.
Definition: When enabled, the check digit character is sent along with the symbol
data. When disabled, symbol data is sent without the check digit.
Serial Cmd: <K471,status,start & stop match,start & stop match output,large inter-
character gap,fixed symbol length status,fixed symbol length,check digit
type,check digit output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Vue de la page 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 225 226

Commentaires sur ces manuels

Pas de commentaire