Chapter 9 Diagnostics
MS-9 Scanner User’s Manual 9-7
Laser High
When enabled, a message is transmitted whenever the laser current exceeds a factory-
calibrated reference value which cannot be altered. The message repeats once every 30
minutes until the condition is corrected.
Laser High Status
Laser High Message
Usage: Alerts the user to impending laser failure. (Contact your service repre-
sentative.)
Definition: Enables the Laser High message.
Serial Cmd: <K400,warning message status,laser high status,laser low status,
novram corrupt warning status>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Defines the Laser High message.
Serial Cmd: <K404,laser high message>
Default: HIGH_LASER
Options: Any 1 to 10 character ASCII string except NUL, <, or >.