Appendices
MS-9 Scanner User’s Manual A-5
Appendix B — Electrical Specifications
Maximum Operating Power: 6.5 Watts
Cabling: Power Input: 10 to 28 VDC, 200 mV p-p max. ripple, 185 mA @ 24 VDC (typical)
Trigger, New Master: 4.5 to 28 VDC (optoisolated)
OMR & New Master Trigger Input: Optoisolated, 10 to 28 VDC Outputs (1,2,3): 1 to 28 VDC
(optoisolated) rated
(I
CE
<100 mA @24 VDC, current limited by user)
3-foot cable terminated with a 15-pin high density D-Sub connector plug.
Table A-2 MS-9 Host Connector, 15-pin
Pin
Host
RS232
Host & Aux
RS232
Host
RS422/485
In/
Out
Figure A-4 MS-9 Connector
1 Power +10 to 28 VDC In
2 TxD TxD TxD (–) Out
3 RxD RxD RxD (–) In
4 Power/Signal ground
5 Trigger (–) In
6 RTS Aux TxD TxD (+) Out
7 Output 1 (+) Out
mm
5
10
100
150
200
250
50
0
0
in.
Range
Scan Width
in.
mm 100 150 20050050100150200
550
MS-911
Typical scan
cone >90%
LD .508 mm
.020 in.
LD .254 mm
.010 in.
LD .190 mm
.0075 in.
LD .381 mm
.015 in.
HD .127 mm
.005 in.
HD .190 mm
.0075 in.
LD = medium density
HD = high density
Figure A-3 MS-9
Read Range Graph
Narrow-
bar-
width
Low Density
High
Density
Visible Ink
Invisible
Ink
.005"
(.127 mm)
1.75" to 3"
(44 to 76 mm)
.0075"
(.190 mm)
2” to 5”
(51 to 127 mm)
1.5" to 4"
(38 to 101 mm)
.010"
(.254 mm)
1.5” to 6”
(38 to 152 mm)
1.5" to 4"
(38 to 101mm)
.015"
(.381 mm)
1” to 7”
(25 to 178 mm)
1.5" to 6"
(38 to 152 mm)
.020"
(.508 mm)
1” to 9”
(25 to 229 mm)
1.5" to 6"
(38 to 152 mm)
1
5
10
15
11
6