Chapter 8 I/0 Parameters
MS-9 Scanner User’s Manual 8-11
Output 1 Parameters
Output On
Note: If Output On is set to Mismatch or Noread, Match, or Mismatch, a transition
(switching) will not occur unless Matchcode Type is enabled and a master symbol is
loaded into memory.
Mismatch or Noread
Activates discrete output when the symbol data does not match that of the master sym-
bol or the symbol has not been decoded before the end of the read cycle.
Match
Activates a discrete output when the symbol data matches the master symbol.
Note: If you want to output for a good read and Matchcode is not enabled, you can
enable any output for Match.
Mismatch
Activates a discrete output whenever the symbol data does not match that of the mas-
ter symbol.
Noread
Activates a discrete output whenever the symbol data is not decoded before the end
of the read cycle.
Trend Analysis
Activates discrete output when a trend analysis condition is met, depending on the
trend analysis option enabled.
Usage: This option provides switching to host software to control external
devices such as PLCs and relays. It is useful for routing and sorting and to
prevent mis-packaging and mis-routing.
Definition: Sets the discrete output functions for specific user-selected conditions.
Definition: Allows the user to set the conditions under which an output (or out-
puts) will be activated.
Serial Cmd: <K810,output on,active state,pulse width,output mode,trend anal-
ysis mode,trigger evaluation period,number to output on,decodes
per trigger>
Default: Noread
Options: 0 = Mismatch or Noread
1 = Match
2 = Mismatch
3 = Noread
4 = Trend Analysis
5 = Good Read