Chapter 9 Raster/Laser Control
MS-880 Industrial Long Range Scanner User’s Manual 9-9
9–Raster/Laser Con-
Raster/Laser by Embedded Menu
To acc ess the Raster/Laser Framing menu, send <@> to open the Autocalibra-
tion Setup menu (figure 6-5 on page 6-8) and type the number 2.
Figure 9-3 Embedded Calibration Results Menu
Raster Settings
Type the letter T to increment the Top Offset and an R to decrement. Notice that the
Top Offset reading at the bottom of the menu changes accordingly.
Type the letter B to increment the Bottom Offset and V to decrement.
Sweep Rate, Raster Status, and Raster On/Off are explained more fully in “Raster
Setup” on page 9-3.
Laser Settings
Laser settings are also dynamically updated at the bottom of the menu.
Full instructions and menus for laser operations can be found in “Laser Setup” on page
9-6.
Press the enter key (CR) to return to the main calibration menu or Esc to leave the
Auto Calibration Setup menu entirely.