Vue de la page 93
Code 39
5-10 MS-880 Industrial Long Range Scanner User’s Manual
5–Codes
Full ASCII Set (Code 39
Definition: Standard Code 39 encodes 43 characters; zero through nine, capital “A
through capital “Z”, minus symbol, plus symbol, forward slash, space,
decimal point, dollar sign and percent symbol. When Full ASCII Set is
enabled, the scanner can read the full ASCII character set, from 0 to
255.
Usage: Must be enabled when reading characters outside the standard charac-
ter set (0-9, A-Z, etc.)
User must know in advance whether or not to use Full ASCII Set
option. Since Full ASCII Set requires two code words to encode one
character, it is less efficient.
Serial Cmd: <K470,status,check digit status,check digit output,large intercharacter
gap,fixed code length status,fixed code length,full ASCII set>
Default: Disabled
Options: 0 = Disabled 1 = Enabled