Appendix I
A-24 MS-880 Industrial Long Range Scanner User’s Manual
Appendices
Appendix I — Defaulting/Saving/Initializing
Defaults are original or saved settings. Defaulting occurs when default settings (from
flash or user-saved NOVRAM) are restored. Defaulting might be necessary if you have
make temporary changes, communications between the scanner and another device are
lost or interrupted, or you are using incompatible equipment (for example, a terminal
that is set at 9600 baud communicating with a scanner that is set at 38.4K baud).
Initializing occurs whenever any command or set of commands is implemented.
Active Memory (SRAM) is where the scanner’s active settings are stored during use.
These are not available on power-up.
User-saved NOVRAM (non-volatile random access memory) is where the scanner’s
operating parameters are stored for power-on. It can be changed by user command.
Flash Defaults is where the scanner’s default download/boot programs are stored. It
can only be changed by downloading application/boot codes.
1
Defaulting
Restore NOVRAM Defaults to Active Memory
• Restores user-defined NOVRAM settings to active
memory.
• Initializes serial configuration commands in
active memory and resets counters to zero.
By Serial Command
Send <An> command to the scanner.
By ESP (There is no equivalent ESP command.)
Restore Flash Defaults to Active Memory
• Restores flash defaults to memory.
• Initializes serial configuration commands in
active memory and resets counters to zero.
• Does not save settings to NOVRAM for power-on.
By Serial Command
Send <Ad> command to the scanner.
By ESP
1. Right-click in the configuration window and
select Default All ESP Settings.
2. Right-click and select Save to Scanner, Send and Save.
1. See your Microscan sales representative to access the latest application codes.
<An>
Flash
Defaults
User-Saved
NOVRAM
Initialize
Active
Memory
<Ad>
Flash
Defaults
User-Saved
NOVRAM
Initialize
Active
Memory