Microscan MS-4X Manuel d'utilisateur Page 39

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 312
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 38
Chapter 2 Communications
MS-880 Industrial Long Range Scanner User’s Manual 2-9
2–Communications
Tra ns par en t Mo d e
Definition: In Transparent mode data is passed between the auxiliary port and
the host. The scanner buffers data from the auxiliary port and echoes
the keyed data on the auxiliary port.
Auxiliary port data is passed through to the
host whenever a return key is pressed at the
auxiliary port or whenever bar code data is
sent. If sent with bar code data, it is processed
on a first-in/first-out basis.
Auxiliary port data to the host is always sent
with a preamble and a postamble.
If the scanner is in a polled mode to the host,
auxiliary port data will still pass through.
<D> is the only command accepted by the scanner from the auxiliary
port. All other commands will pass through to the host.
Data initiated from the Scanner
Transmission to the auxiliary port occurs
immediately upon a good read.
Scan data to the auxiliary port does not include
a preamble or a postamble.
Communications with the auxiliary port is
always in Point-to-Point protocol, even if the
host is in a polled protocol mode.
Data initiated from the Host
All host data is echoed to the auxiliary port in
unpolled mode.
Usage: A common application, in conjunction with handheld scanners, is one
that employs an auxiliary readout to detect mis-applied bar code labels.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
1 = Transparent
Scanner
Host
Aux
Port
Scanner
Host
Aux
Port
Scanner
Host
Aux
Port
Vue de la page 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 311 312

Commentaires sur ces manuels

Pas de commentaire