Codabar
5-12 MS-880 Industrial Long Range Scanner User’s Manual
5–Codes
Large Intercharacter Gap (Codabar)
Fixed Code Length Status (Codabar)
Fixed Code Length (Codabar)
Note: Fixed Code Length Status must be enabled for Fixed Code Length to take
effect.
Note: Because of symbology limitations, setting Code Length to any number less
than four will produce undetermined results.
Definition: Instructs the scanner to read symbols with gaps between characters
exceeding three times the narrow element width.
Usage: It is helpful for reading symbols that are printed out of specification.
Caution: Do not use Large Intercharacter Gap with Narrow Mar-
gins enabled since enabling Large Intercharacter Gap (over 3x)
could cause a narrow margins (5x) to be interpreted as an intercharac-
ter gap.
Serial Cmd: <K471, status,start & stop match,start & stop output match,large
intercharacter gap,fixed code length status,fixed fixed code
length,check digit type,check digit output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: When enabled, the scanner will check the label length against the fixed
code length field. If disabled any length would be considered a valid
label.
Serial Cmd: <K471, status,start & stop match,start & stop match output,large
intercharacter gap,fixed code length status,fixed code length,check
digit type,check digit output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Specifies the exact number of characters that the scanner will recognize
(this does not include start and stop and check digit characters). The
scanner ignores any code not having the specified length.
Usage: Fixed Code Length helps prevent truncations and increases data
integrity by ensuring that only one symbol length will be accepted.
Serial Cmd: <K471, status,start & stop match,start & stop match output,large
intercharacter gap,fixed code length status,fixed code length,check
digit type,check digit output>
Default: 10
Options: 1 to 128