High Temperature Threshold
15-8 MS-880 Industrial Long Range Scanner User’s Manual
15–Diagnostics
High Temperature Threshold
A message can be defined that will display when a user-set High Temperature
Threshold has been reached. The message repeats once every 30 minutes until the
condition is corrected. This value is a reference to the external ambient temperature
in the environment around the scanner.
High Temperature Degrees
High Temperature Message
Definition: A user can set a temperature value that when exceeded will cause a
high temperature message to be displayed. If High Temperature
Threshold is set to zero, then the warning message will be disabled
Usage: Helps ensure that the scanner is being used within its temperature
specification. Also, since hotter environments tend to shorten the life of
electronics components, a user may want to set the temperature
threshold closer to the nominal temperature of 25°.
Serial Cmd: <K402,degrees,message>
Default: 50° Celsius
Options: 0° to 50°, zero disables.
Definition: The user can enter a 10-character message that will be displayed
whenever High Temperature Threshold is exceeded.
Serial Cmd: <K402,degrees,message>
Default: HIGH_TEMP
Options: Any 1 to 10 character ASCII string except NUL, <, or >.