Microscan MS-4X Manuel d'utilisateur Page 140

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 312
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 139
Optoelectric Database Modes
8-8 MS-880 Industrial Long Range Scanner User’s Manual
8–Optoelectrics
Process: To use Control Trigger:
1. Setup your application’s labels by code type/size in the various
positions and/or code type/size at which they will likely appear.
2. Sketch out a diagram as in figure 8-1.
3. Setup your sensors or other con-
trols. For example, the three object
sensors, 1, 2 & 3, are connected to
input 1, new master pin, and trigger
input respectively. The bar coded
packages on the left are numbered
here according to their database
index numbers. Package #7 will
cross all three of the sensors and
thus activate the settings for index
#7 as shown.
In this scenario only four index set-
tings are possible. However, up to
seven combinations are possible
with other input devices such as
PLCs.
You can also enable/disable any
combination controls by clicking on
the Control Trigger Status buttons
on the bottom of the Control Trigger Map. The red buttons
indicate active states on the three control triggers. The combi-
nation of active/inactive triggers determines the focus, gain, and
tracking settings that will be applied during a read cycle. For
example, if only Control Trigger 1 is active, the focus, gain, and
tracking values that appear in the top row will be applied.
2
3
1
7
5
3
1
Figure 8-1 Control Trigger
Inputs
Figure 8-2 ESP Control Trigger Setup