Vue de la page 71
Trigger Mode
4-6 MS-880 Industrial Long Range Scanner User’s Manual
4–Read Cycle/Trig-
External Trigger Level
Important: Level and Edge apply to the active logic state (Active Off (I
OFF
) or Active
On (I
ON
)) that exists while the object is in a read cycle, between the rising edge and
falling edge. Rising edge is the trigger signal associated with the appearance of an
object. Falling edge is the trigger signal associated with the subsequent disappear-
ance of the object.
Note: In External Trigger Level, sending a Non-delimited Start Serial Character will
start a read cycle and sending a Non-delimited Stop Serial Character will end it. See
“Start and End Trigger Characters (non-delimited)” in chapter 4.
Definition: External Trigger Level allows the read cycle (active state) to begin
when a trigger (change of state) from an external sensing device is
received. The read cycle endures until the object moves out of the sen-
sor range and the active trigger state changes again.
Usage: This mode is effective in an application where the speeds of the convey-
ing apparatus are variable and the time the scanner spends scanning
each object is not predictable. It also allows the user to determine if a
noread has occurred.
Serial Cmd: <K200,2>
Figure 4-1 Trigger Level
Initiate Read Cycle:
Object # 1, moving in front of the detector
beam, causes a change in the trigger state,
initiating the read cycle.
End Read Cycle:
The same object, moving out of the detector
beam, causes another change in the trigger
state, ending the read cycle.
Associated waveforms assume
External Trigger State is set
to Active On.
Vue de la page 71