Auxiliary Port
2-12 MS-880 Industrial Long Range Scanner User’s Manual
2–Communications
Daisy Chain Mode
Note: See also “Daisy Chain Autoconfigure” on page 2-27.
Definition: In a daisy chain application, scanners are connected in tandem or
“daisy chain” and decoded data is relayed from one scanner to another
on up to the host.
A master scanner has its host port linked to the host computer and its
auxiliary port linked to the host port of the first “slave” scanner in the
chain. Thereafter, each slave’s auxiliary port is linked to the host port of
the slave that is further from the host in the daisy chain.
Each scanner in the daisy chain can be assigned an ID that accompa-
nies any data that it sends.
Usage: Useful in applications where:
A bar code label might be scanned in both ladder and picket fence direc-
tions.
A bar code label may be present on multiple sides of a package.
Bar code labels are presented at different depths.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Options: 4 = Daisy chain
Function: Before the master scanner times out, it checks its auxiliary port for
data. It should be set to wait at least 30 mS for each slave in the daisy
chain. (See “Timeout Duration” on page 4-15.) If no data is received
within the read cycle timeout, the master sends a noread message to
the host. Otherwise the complete data is sent.
If for example the master scanner is set to timeout in 120 ms, the first
slave scanner downstream might be set to 90 ms, the next to 30 ms,
and so forth, thus assuring that at least 30 mS elapses between trans-
missions.
a
Daisy-chained scanners can send a series of labels by enabling Multila-
bel and a common multilabel separator. If the master scanner does not
receive the expected number of labels, noread messages are appended
to the data string to make up the difference between the number of
labels enabled in Multilabel and the number of labels read.
For example, a master and two slave scanners have Number of Labels set
to 3 and Multilabel Separator defined as %. If the master and the first
slave scanner do not find labels, but the next slave scanner registers a good
read, the transmitted results would be: label data % noread % noread.
a. The above example is based on the best case. Other factors such as baud rate, dynamic focus timing,
number of characters in a given symbol, and the number of slaves in the daisy chain can affect timing
and may need to be included in your calculations for complete accuracy.