Extraction Mode
13-6 MS-880 Industrial Long Range Scanner User’s Manual
13–Output Format
Extraction by Serial Command
Output #
Start Position
Length
Definition: An Output # identifies the step involved in an output format process.
For example, if the routine involves a series of 6 Extraction and/or
Insertion steps, each of these steps is controlled by assigning sequen-
tial output numbers from 1 to 4.
ESP: Output # appears in the Advanced Formatting tab.
Serial Cmd: <K740,output #,start position,length>
Default: (none) Must be entered.
Options: 1 to 100
Definition: Specifies the precise character in the data sequence (from left to right)
where the selection for output begins.
Serial Cmd: <K740,output #,start position,length>
Default: 0 (Zero is disabled. It also marks the end of a format cell array.)
Options: 0 to maximum characters per label (zero is disabled)
Definition: Specifies the length of the output string.
Serial Cmd: <K740,output #,start position,length>
Default: 0
Options: 0 to maximum characters per label (zero is disabled)