Chapter 11 Matchcode
MS-880 Industrial Long Range Scanner User’s Manual 11-5
11–Matchcode
Matchcode Type
Definition: Allows the user to choose the way that master labels will be compared
with subsequently scanned labels.
Note: First set Triggering Mode to External or Serial.
ESP:
Serial Cmd: <K223,matchcode type,sequential matching,match start position,
match length,wild card character,sequence on noread,sequence on
mismatch>
Default: Disabled
Options: 0 = Disabled
1 = Enabled
2 = Sequential
3 = Wild Card
Disabled: Has no effect on operations.
Enabled: Instructs the scanner to compare labels or portions of labels with the
master label.
Wild Card: Allows the user to enter user defined wild card characters in the master
label.
Sequential
Matching:
Instructs the scanner to sequence after each match (numeric only) and
compare labels or portions of labels for sequential numbers.
Note: If Matchcode Type is set to Sequential, Number of Labels
will default back to 1 (if set to any number greater than 1).