Microscan MS-4X Manuel d'utilisateur Page 178

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 312
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 177
New Master Pin
11-16 MS-880 Industrial Long Range Scanner User’s Manual
11–Matchcode
New Master Pin
After New Master Pin has been enabled and the pin activated, decodes will be saved
in the master database beginning with master label #1. If the scanner is configured for
a multilabel read cycle (Number of Labels is greater than 1), the remaining decodes
will be saved in each consecutive master label location. For example, if Number of
Labels is set to 3 and New Master Pin is then activated, at the end of the next read
cycle, the decoded bar code labels will be saved as master labels 1, 2, and 3.
Definition: After New Master Pin is enabled, a pulse can be received on the new
master pin which will cause the scanner to record the next decoded bar
code label(s) as the new master label(s).
It is important to note that the enabling New Master Pin does not in
itself cause a master label to be recorded. The master pin must then be
activated momentarily (for a minimum of 10 ms) before a master label
can be scanned into memory. (See Table A-7, “Host 25-pin Connector,
on page A-8and Figure 16-7, Wiring Box PCB, on page 16- 8.)
Usage: Some applications require the line worker to change the master label.
This can be done by installing a switch at the location of the scanner. It
is very common to have a keyed switch so that accidental switching
does not occur.
ESP: In the Matchcode menu, select New Master Pin, double-click on Dis-
abled and select Enabled.
Serial Cmd: <K225,status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Vue de la page 177
1 2 ... 173 174 175 176 177 178 179 180 181 182 183 ... 311 312

Commentaires sur ces manuels

Pas de commentaire