Chapter 10 Scanner Setup
MS-880 Industrial Long Range Scanner User’s Manual 10-7
10–Scanner Setup
Transition Counter
Transition Counter Status
Transition Counter Threshold
Definition: During the read cycle, the scanner counts the number of bar and space
transitions defined in the Transition Counter Threshold. If the count
matches or exceeds the threshold, the scanner will perform AGC rou-
tines.
Serial Cmd: <K505,transition counter status,transition counter threshold>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
Definition: Determines the number of bar/space transitions that must be read
before a label is considered present and AGC can be resolved.
Usage: Can be useful in certain application where extraneous objects in the
field of view might require a higher threshold.
Serial Cmd: <K505,transition counter status,transition counter threshold>
Default: 14
Options: 0 to 255