Ordered Output/Filtering
13-14 MS-880 Industrial Long Range Scanner User’s Manual
13–Output Format
For example:
Filter data “123*” matches “123”, “123456”, “123ABC” but not “12”.
Filter data “123*AB?C” will be interpreted as “123*”
Filter data “123?A?” matches “1234AB”, “123BAT”, but not “1234A” or “123BATS”.
Filter data “12??*” matches “1234”, “123456”, “123ABC”, but not “12”, “123”.
Filter data “123?A*” matches “1234A, “123BA, “123BATS”, but not “1234”, “1234C”.
For example:
<K745,1> enables Output Filters #1 setting.
<K745,3> enables Output Filters #1 to filter #3’s setting.
<K745,0> disables all output filters. The reader will not perform any filtered output.
Data
Number of Filters
Definition: User-assigned data that the scanner will search for.
Serial Cmd: <K744,filter#,code type,length,wildcard character,placeholder charac-
ter,data>
Default: Null
Options: Any pairing of hex digits representing ASCII characters;
e.g., 41422A = “AB*”
(00 = disabled)
Definition: The number of filters that labels will be compared against, up to the
specified number. For example, entering 7 means that filters #1
through #7 will be enabled.
Serial Cmd: <K745,number of filters involved>
Default: 0
Options: 0 to 12
Any number from 1 to 12 enables Output Filtering. A zero (0) disables
Output Filtering. The reader will not perform any filtered output.