Chapter 2 Communications
MS-880 Industrial Long Range Scanner User’s Manual 2-5
2–Communications
Host Port Parameters
Important: This applies only to the 25-pin port and wiring box connections (not
for 9-pin port).
Note: See “Select the Communications Ports” on page 1-8 for 9-pin host port parame-
ters.
Baud Rate, Host Port
Parity, Host Port
Stop Bits, Host Port
Definition: The rate at which the scanner and host transfer data back and forth.
Usage: Can be used to transfer data faster or to match host port settings.
Serial Cmd: <K100,baud rate,parity,stop bits,data bits>
Default: 9600
Options: 1 = 1200 4 = 9600 7 = 57.6K
2 = 2400 5 = 19.2K 8 = 115.2K
3 = 4800 6 = 38.4K
Definition: An error detection routine in which one data bit in each character is set to
1 or 0 so that the total number of 1 bits in the data field is even or odd.
Usage: Only changed if necessary to match host setting.
Serial Cmd: <K100,baud rate,parity,stop bits,data bits>
Default: Even
Options: 0 = None 1 = Even 2 = Odd
Definition: One or two bits added to the end of each character to indicate the end
of the character.
Usage: Only changed if necessary to match host setting.
Serial Cmd: <K100,baud rate,parity,stop bits,data bits>
Default: One
Options: 0 = One 1 = Two