Vue de la page 96
Chapter 5 Codes
MS-880 Industrial Long Range Scanner User’s Manual 5-13
5–Codes
Check Digit Type (Codabar)
Check Digit Output (Codabar)
Definition: Allows the user to select the check digit type Codabar will use.
Serial Cmd: <K471,status,start & stop match,start & stop match output,large
intercharacter gap,fixed code length status,fixed code length,check
digit type,check digit output>
Default: Disabled
Options: 0 = Disabled
1 = Modulus 16
2 = NW 7
3 = Both
Modulus 16: Used in the photo-finishing market.
NW 7: Used in Japanese markets.
Definition: When enabled, the check digit character is sent along with the bar code
data. When disabled, bar code data is sent without the check digit.
Usage: For additional security a check digit can be added to the bar code sym-
bol.
Serial Cmd: <K471,status,start & stop match,start & stop match output,large
intercharacter gap,fixed code length status,fixed code length,check
digit type,check digit output>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Vue de la page 96