Diagnostic Outputs
14-12 MS-880 Industrial Long Range Scanner User’s Manual
14–Discrete I/0
Output
Status
Note: When enabled, the error condition will override all other operational modes
configured for the output.
Definition: Selects the status settings for one of three outputs (Output 1, Output
2, or Output 3).
Function: Each of the three outputs is independently associated with ten status
settings. The settings can be accessed to verify/change one output at
a time.
Serial Cmd: <K713, output #,status1,status2,status3,status4,status5,status6,
status7,status8,status9>
Options: 1 = Logic output 1
2 = Logic output 2
3 = Logic output 3
Definition: When enabled, the error condition will cause the selected output to
become active.
Serial Cmd: <K713, output #,status1,status2,status3,status4,status5,
status6,status7,status8,status9>
Default: Disabled (each can be independently enabled)
Options: 0 = Disabled
1 = Enabled
status1 = Laser Current Low
status2 = Laser Current High
status3 = Temperature Low
status4 = Temperature High
status5 = Diagnostics Flash Corrupt
status6 = Laser Ref. Corrupt
status7 = Product lifetime exceeded
status8 = Factory settings defaulted
status9 = Customer settings defaulted