Microscan MS-4X Manuel d'utilisateur Page 149

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 312
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 148
Chapter 9 Raster/Laser Control
MS-880 Industrial Long Range Scanner User’s Manual 9-5
9–Raster/Laser Con-
Raster Sweep Rate
Table 9-1 Maximum Sweep Rates at Selected Sweep Arcs
Definition: The raster sweep rate is the number of sweeps per second the raster mirror
completes. A sweep is one pass of the raster, up or down. The maximum
sweep rate is limited by the size of the arc the raster must move through.
Usage: If your application allows it, a slower sweep rate can produce more scans
per second and better read rates. To determine the minimum read rate for
your application, see “Raster Picket Fence Calculation” on page A-32.
Serial Cmd: <K506,status,top offset,bottom offset,raster sweep rate,read cycle on/off>
Default: 10
Options: 0 to 30
Raster Sweep Arc
Maximum Sweeps
per Second
0 to 10° 30
11 to 20° 20
21 to 30° 10
Vue de la page 148
1 2 ... 144 145 146 147 148 149 150 151 152 153 154 ... 311 312

Commentaires sur ces manuels

Pas de commentaire