Chapter 11 Matchcode
MS-880 Industrial Long Range Scanner User’s Manual 11-11
11–Matchcode
Master Label Database
Important: Master Label Database is used only for comparing entire bar codes,
when Sequential and Wild Card are NOT enabled, and Start Position is equal to 0.
Master Label Database Overview
Master Label Database Size
Definition: Allows you to define up to 10 master labels as the master label data-
base, which can be entered by keyboard, scanned-in, displayed, or
deleted by serial or ESP commands.
Usage: Useful where more than one master label is required, as in a Multilabel
setup, for matching and other matchcode operations.
Definition: Master Label Data Base Size allows you to select 1 to 10 master
labels for the master label database.
ESP: Click the Matchcode button to access the master label:
First set the number of master labels you want to include by double-
clicking Database Size and entering the number.
Serial Cmd: <master label data base size>
Note: You must follow this command with a save command <A> or
<Z>.
Default: 1
Options: 1 to 10
Double-click here and set the master
label database size.